Welcome to the official website of kingda
  • Product categories
    Contact us

    Dongguan city, kingda plastic insulation board co., LTD

    Contact: manager zhao

    Mobile phone: 13509011897

    Telephone:

    Fax:

    Email:1440816890@qq.com

    Website:www.qdjnkj.com

    Address: Zhongtang town Zhancui Nan di Industrial area

    Your location:主页 > Product > Kanda XPS - flame retardant board >
    Qanda B1 extruded board
    Product name:

    Qanda B1 extruded board


    specification:
    Model:
    The price:
    Product description

    B1 extruded board

    Qindar extrusion XPS extrusion heat shield

    Qinda extrusion board is a kind of high density rigid foam board (XPS) made of polystyrene resin plus other auxiliary materials and polymer, which is mixed by heating and injected with catalyst, and then extruded and pressed into shape. This unique closed-cell honeycomb structure makes the qinta plate have extremely low water absorption (almost no absorption), low thermal conductivity, high compressive resistance, anti-aging (almost no aging decomposition in normal use).




    Refractory B1 extruded board can also be lit, with combustible B2 board what is the difference?


    First of all, it has been explained above that the extruded board belongs to combustible materials, so no matter whether the combustible B2 board or the refractory B1 board encounters the open flame, it is a normal phenomenon. However, it is important to note that the extruded sheet has a very good self-extinguishing characteristic. Moreover, the self-extinguishing property of refractory B1 class board is better than that of combustible B2 class board. As for the difference between combustible B2 class board and refractory B1 class board before, according to gb8624-1997 "classification method of combustion performance of building materials". In addition to meeting the flammability level B2 standard, class B1 materials should also meet the requirements of flue gas temperature and smoke density specified in the standard. Generally, a simple lighter test is conducted on the extruded board, and it is difficult to see the obvious difference between combustible B2 and refractory B1, but at least it can be seen that the refractory B1 board after leaving the fire is shorter than combustible B2 board flame spread length, shorter combustion time and less smoke.


    Related labels:
    Source:http://www.qdjnkj.com/qd-xps--zrb/62.html
    Release date:2020-03-25
    Related news
    Related products

    QQ

    The phone

    Mobile phone13509011897

    Qr code

    分享